Configuration Manager:

High-Performance kit for programming the DS120. Includes CD-ROM, Hardlock (USB or parallel) and connecting cable. Runs on Windows® 95, 98, 2000 NT.

DS120 PSV 3/1 LMI

Load Indication and Overload protection for:

· Gantry Cranes

· Container Cranes

· Straddle Carriers

· Harbour Cranes

· EOT Cranes

 

All configurations and values can be programmed by external PSION® handheld terminal (menu controlled)

 

All standard sensors applicable (load, pressure, angle, length, and all-purpose)

 

Averaging of measured values

 

Mathematical data processing (+, -, *, /, min, max)

 

Auto check of sensors and entered data

 

Nonlinear data processing (CURVE module)

Free adaptation of the display Interfaces for external display devices

 

Supply voltages 12, 24 VDC or 48,115, 230 VAC

Available without display

Up to 4 lifetime counters

Extra card with 8 additional relays

Crane specific pre-programming

The Programmable Switching Amplifier DS 120 displays and monitors precisely analogue data from load sensors as used on cranes such as load pins, tensiometers, compression load cells and many more.

 

The processing of these data can be programmed freely by means of a great variety of available modules. The load data from the crane can be added, subtracted, multiplied and compared to fixed and variable values.

 

Different crane configurations are considered by digital inputs which can activate specific settings inside the DS 120.

 

Finally the data are controlled by comparison with the crane's load maximum levels.

 

In case of any unsafe condition due to over-, under- or eccentric load, sensor fault or any other error, the respective relays will immediately be switched off in order to set the crane to a safe condition again. Special dynamic software-modules will detect snag-conditions and can protect the crane respectively.

 

Also Available with:

PAT Kruger Graphidis,   Large Led Display

ST 9 Console,  Harbour Crane Display

All kinds of Sensors